Difference between revisions of "Sigrok-cli"

From sigrok
Jump to navigation Jump to search
(Update sigrok-cli manpage, document how to generate the wiki version.)
(add screenshot section)
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{DISPLAYTITLE:sigrok-cli}}
{{DISPLAYTITLE:sigrok-cli}}
'''sigrok-cli''' is a command-line frontend for sigrok.
'''sigrok-cli''' (sometimes abbreviated as "cli") is a command-line frontend for sigrok.


It is licensed under the terms of the '''GNU GPL, version 3 or later'''.
It is licensed under the terms of the '''GNU GPL, version 3 or later'''.


== manpage ==
== Getting the code ==
 
$ '''git clone git://sigrok.org/sigrok-cli'''
 
You can also [http://sigrok.org/gitweb/?p=sigrok-cli.git;a=tree browse the source code] via gitweb.
 
== Distribution packages ==
 
See [[Downloads#Binaries_and_distribution_packages|Downloads]].
 
== Building from source ==
 
See [[Building]].
 
== Manpage ==
<!-- Generated by: "LC_ALL=C nroff -man doc/sigrok-cli.1 | col -b". -->
<!-- Generated by: "LC_ALL=C nroff -man doc/sigrok-cli.1 | col -b". -->
<pre>
<pre>
Line 34: Line 48:


       -V, --version
       -V, --version
      Show sigrok-cli version, and information about supported hard-
      Show sigrok-cli version and the versions of libraries used.
      ware drivers, input file formats, output file formats, and pro-
 
      tocol decoders.
      -L, --list-supported
      Show information about supported hardware drivers, input file
      formats, output file formats, and protocol decoders.


       -d, --driver <drivername>
       -d, --driver <drivername>
      A driver must always be selected (unless doing a global scan).
      A driver must always be selected (unless doing a global scan).
      Use the -V option to get a list of available drivers.
      Use the -L (--list-supported) option to get a list of available
      drivers.


      Drivers  can  take  options,  in the form key=value separated by
      Drivers  can  take  options,  in the form key=value separated by
Line 49: Line 66:
      the Openbench Logic Sniffer:
      the Openbench Logic Sniffer:


$ sigrok-cli --driver=ols:conn=/dev/ttyACM0
$ sigrok-cli --driver=ols:conn=/dev/ttyACM0 [...]


      Some USB devices don't use a unique VendorID/ProductID  combina-
      Some USB devices don't use a unique VendorID/ProductID  combina-
Line 55: Line 72:
      conn option, using either VendorID.ProductID or bus.address:
      conn option, using either VendorID.ProductID or bus.address:


$ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008
      USB VendorID.ProductID example:


       -c, --config <device>
$ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 [...]
 
      USB bus.address example:
 
$ sigrok-cli --driver=uni-t-ut61e:conn=4.6 [...]
 
       -c, --config <deviceoption>
      A colon-separated list of  device  options,  where  each option
      A colon-separated list of  device  options,  where  each option
      takes the form key=value.  For example, to set the samplerate to
      takes the form key=value.  For example, to set the samplerate to
Line 63: Line 86:
      specify
      specify


$ sigrok-cli --driver=fx2lafw --config samplerate=1m
$ sigrok-cli -d fx2lafw --config samplerate=1m [...]


      Samplerate  is  an  option  common  to most logic analyzers. The
      Samplerate  is  an  option  common  to most logic analyzers. The
Line 70: Line 93:
      alent:
      alent:


$ sigrok-cli --driver fx2lafw --config samplerate=1000000
$ sigrok-cli -d fx2lafw --config samplerate=1000000 [...]


$ sigrok-cli --driver fx2lafw --config samplerate=1m
$ sigrok-cli -d fx2lafw --config samplerate=1m [...]


$ sigrok-cli --driver fx2lafw --config "samplerate=1 MHz"
$ sigrok-cli -d fx2lafw --config "samplerate=1 MHz" [...]


       -i, --input-file <filename>
       -i, --input-file <filename>
      Load input from a file instead of a  hardware  device.  If the
      Load input from a file instead of a  hardware  device.  You can
      --input-format option is not supplied, sigrok-cli attempts to
      specify  "-" to use stdin as input. If the --input-format option
      autodetect the file format of the input file.
      is not supplied, sigrok-cli attempts to autodetect the file for-
      mat of the input file.
 
      Example for loading a sigrok session file:
 
$ sigrok-cli -i example.sr [...]
 
      Example for loading a WAV file (autodetection of input format):
 
$ sigrok-cli -i example.wav [...]
 
      Example  for  loading  a VCD  file from stdin (autodetection of
      input format):
 
$ cat example.vcd | sigrok-cli -i - [...]


       -I, --input-format <format>
       -I, --input-format <format>
Line 85: Line 122:
      If  this option is not supplied (in addition to --input-file),
      If  this option is not supplied (in addition to --input-file),
      sigrok-cli attempts to autodetect the file format of  the  input
      sigrok-cli attempts to autodetect the file format of  the  input
      file.  Use  the  -V option to see a list of available input for-
      file.  Use  the  -L  (--list-supported)  option to see a list of
      mats.
      available input formats.


      The format name may optionally be followed by a  colon-separated
      The format name may optionally be followed by a  colon-separated
      list of options, where each option takes the form key=value.
      list of options, where each option takes the form key=value.
      Example for loading a binary file with options:
$ sigrok-cli -i example.bin
    -I binary:numchannels=4:samplerate=1mhz [...]


       -o, --output-file <filename>
       -o, --output-file <filename>
Line 96: Line 138:
      mat. This can be changed with the --output-format option.
      mat. This can be changed with the --output-format option.


       -O, --output-format <formatname>
      Example for saving data in the sigrok session format:
      Set the output format to use. Use the -V option to see a list of
 
      available output formats.
$ sigrok-cli [...] -o example.sr
 
       -O, --output-format <format>
      Set the output format to use. Use the -L (--list-supported)
      option to see a list of available output formats.


      The format name may optionally be followed by a  colon-separated
      The format name may optionally be followed by a  colon-separated
      list of options, where each option takes the form key=value.
      list of options, where each option takes the form key=value.


      Supported formats  currently  include bits, hex, ascii, binary,
      For example, the bits or hex formats, for an ASCII bit or ASCII
      vcd, ols, gnuplot, chronovu-la8, csv, and analog.
      hexadecimal display, can take a "width" option, specifying the
 
      number of samples (in bits) to display per line. Thus -O
      The bits or hex formats, for an ASCII bit or ASCII hexadecimal
      hex:width=128 will display 128 bits per line, in hexadecimal:
      display, can take a "width" option, specifying the number of
      samples (in bits) to display per line. Thus hex:width=128 will
      display 128 bits per line, in hexadecimal:


      0:ffff ffff ffff ffff ffff ffff ffff ffff
      0:ffff ffff ffff ffff ffff ffff ffff ffff
      1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
      1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00


      The lines always start with  the channel number (or name, if
      The lines always start with the channel number (or name, if
      defined), followed by a colon. If no format is specified, it
      defined), followed by a colon. If no format is specified, it
      defaults to bits:width=64, like this:
      defaults to bits:width=64, like this:


      0:11111111 11111111 11111111 11111111 [...]
      0:11111111 11111111 11111111 11111111 [...]
      1:11111111 00000000 11111111 00000000 [...]
      1:11111111 00000000 11111111 00000000 [...]
      Example for saving data in the CSV format with options:
$ sigrok-cli [...] -o example.csv -O csv:dedup:header=false
      Notice that boolean options are true when no value  gets speci-
      fied.


       -C, --channels <channellist>
       -C, --channels <channellist>
Line 150: Line 200:


       -g, --channel-group <channel group>
       -g, --channel-group <channel group>
      Specify the channel group to operate on.
      Specify the channel group to operate on. Some  devices  organize
      channels into groups, the settings of which can only be changed
      as a group. The list of channel groups,  if  any,  is  displayed
      with the --show command.


      Some devices organize channels  into  groups,  the  settings  of
      Examples:
      which  can  only be  changed  as  a  group. The list of channel
 
      groups, if any, is displayed with the --show command.
$ sigrok-cli -g CH1 [...]
 
$ sigrok-cli -d demo -g Logic -c pattern=graycode [...]


       -t, --triggers <triggerlist>
       -t, --triggers <triggerlist>
      A comma-separated list of triggers to use, of the form <chan-
      A comma-separated list of triggers to use, of the form <chan-
      nel>=<trigger>. You can use the name or number of the channel,
      nel>=<trigger>. You can use the name or number of the channel,
      and the trigger itself is a series of characters:
      and the trigger itself is a series of characters:


      0 or 1: A low or high value on the pin.
      0 or 1: A low or high value on the pin.
      r or f: A rising or falling value on the pin. An r effectively
      r or f: A rising or falling value on the pin. An r effectively
      corresponds to 01.
      corresponds to 01.
      e: Any kind of change on a pin (either a rising or a falling
      e: Any kind of change on a pin (either a rising or a falling
      edge).
      edge).


      Not every device supports all of these trigger types. Use the
      Not every device supports all of these trigger types. Use the
      --show command to see which triggers your device supports.
      --show command to see which triggers your device supports.


       -w, --wait-trigger
       -w, --wait-trigger
      Don't output any sample data (even if it's actually received
      Don't output any sample data (even if it's actually received
      from the hardware) before the trigger condition is met. In other
      from the hardware) before the trigger condition is met. In other
      words, do not output any pre-trigger data. This option is useful
      words, do not output any pre-trigger data. This option is useful
      if you don't care about the data that came before the trigger
      if you don't care about the data that came before the trigger
      (but the hardware delivers this data to sigrok nonetheless).
      (but the hardware delivers this data to sigrok nonetheless).


       -P, --protocol-decoders <list>
       -P, --protocol-decoders <list>
      This option allows the user to specify a comma-separated list of
      This option allows the user to specify a comma-separated list of
      protocol decoders to be used in this session. The decoders are
      protocol decoders to be used in this session. The decoders are
      specified by their ID, as shown in the --version output.
      specified by their ID, as shown in the -L  (--list-supported)
      output.


      Example:
      Example:
Line 213: Line 269:
      as MOSI, channel 3 as CLK, and channel 0 as CS# signal.
      as MOSI, channel 3 as CLK, and channel 0 as CS# signal.


      -S, --protocol-decoder-stack <stack>
      Notice that the sigrok-cli application does  not support  "name
      This option allows the user to specify a protocol decoder stack,
      matching".  Instead  it's  assumed  that the traces in the input
      i.e.  the way in which one protocol decoder's output gets piped
      stream match the order of the decoder's input signalsor  that
      into another protocol decoder. If not specified, the stack will
      users  explicitly  specify the input channel to decoder signal
      be set up in the same order in which the protocol decoders were
      mapping.
      given with the --protocol-decoders option.


      The decoders are specified by their ID, as shown in the --ver-
      When multiple decoders are specified in the same -P option, they
      sion output. In addition to the -S option, all protocol decoders
      will be stacked on top of each other in the specified order.
      that are used in a stack, must also be specified (together  with
      their options, if any) using the -P parameter.


      Example:
      Example:


      $ sigrok-cli -i <file.sr> -P i2c:sda=4:scl=7,rtc8564
      $ sigrok-cli -i <file.sr> -P i2c,eeprom24xx
    -S i2c,rtc8564
      $ sigrok-cli -i <file.sr> -P uart:baudrate=31250,midi
 
      When multiple -P options are specified, each of them creates one
      decoder stack, which  executes  in  parallel  to other  decoder
      stacks.
 
      Example:


      In  this example, the -S option specifies that the output of the
      $ sigrok-cli -i <file.sr> -P uart:tx=D0:rx=D1 -P timing:data=D2
      i2c decoder is piped into the rtc8564 decoder, i.e., the rtc8564
      decoder is stacked on top of the i2c decoder.


      The  respective protocol decoder options and channel name/number
      assignments must be given using the -P option (you cannot  spec-
      ify them in the -S option).


       -A, --protocol-decoder-annotations <annotations>
       -A, --protocol-decoder-annotations <annotations>
      By  default, only the stack's topmost protocol decoder's annota-
      By  default, all  annotation output of all protocol decoders is
      tion output is shown. With this option another decoder's annota-
      shown. With this option a specific decoder's annotations can  be
      tion can be selected for display, by specifying its ID:
      selected for display, by specifying the decoder ID:


      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c


      If  a  protocol decoder has multiple annotations, you can also
      If  a  protocol decoder has multiple annotation classes, you can
      specify which one of them to show by specifying  its  short
      also specify which one of them to show by specifying  its  short
      description like this:
      description like this:


Line 252: Line 306:
    -A i2c=data-read
    -A i2c=data-read


      Select multiple annotations by separating them with a colon:
      Select multiple annotation  classes  by separating them with a
      colon:


      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
Line 258: Line 313:


      You can also select multiple protocol decoders, with an optional
      You can also select multiple protocol decoders, with an optional
      selected annotation each, by separating them with commas:
      selected annotation class each, by separating them with commas:


      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
Line 265: Line 320:
       -M, --protocol-decoder-meta <pdname>
       -M, --protocol-decoder-meta <pdname>
      When given, show protocol decoder meta output instead of annota-
      When given, show protocol decoder meta output instead of annota-
      tions.   The argument is the name of the decoder whose meta out-
      tions. The argument is the name of the decoder whose meta out-
      put to show.
      put to show.


Line 273: Line 328:


       -B, --protocol-decoder-binary <binaryspec>
       -B, --protocol-decoder-binary <binaryspec>
      When given, decoder "raw" data of various kinds is written to
      When given, decoder "raw" data of various kinds is written to
      stdout instead of annotations (this could be raw binary UART/SPI
      stdout instead of annotations (this could be raw binary UART/SPI
      bytes, or WAV files, PCAP files, PNG files, or anything else;
      bytes, or WAV files, PCAP files, PNG files, or anything else;
      this is entirely dependent on  the decoder and what kinds of
      this is entirely dependent on the decoder and what kinds of
      binary output make sense for that decoder).
      binary output make sense for that decoder).


      No other information is printed to stdout, so this is suitable
      No other information is printed to stdout, so this is suitable
      for piping into other programs or saving to a file.
      for piping into other programs or saving to a file.


      Protocol decoders that support binary output publish a list of
      Protocol decoders that support binary output publish a list of
      binary classes, for example the UART decoder might have "TX" and
      binary classes, for example the UART decoder might have "TX" and
      "RX". To select TX for output, the argument to this option would
      "RX". To select TX for output, the argument to this option would
Line 294: Line 349:
      $ sigrok-cli -i <file.sr> -B uart
      $ sigrok-cli -i <file.sr> -B uart


      (this is only useful in rare cases, generally you would specify
      (this is only useful in rare cases, generally you would specify
      a certain binary class you're interested in)
      a certain binary class you're interested in)


      Not every decoder generates binary output.
      Not every decoder generates binary output.
      --protocol-decoder-samplenum
      When  given,  decoder  annotations  will include sample numbers,
      too.  This allows consumers to receive machine  readable timing
      information.


       -l, --loglevel <level>
       -l, --loglevel <level>
      Set the libsigrok and libsigrokdecode loglevel. At the moment
      Set the libsigrok and libsigrokdecode loglevel. At the moment
      sigrok-cli doesn't support setting the two loglevels indepen-
      sigrok-cli doesn't support setting the two loglevels indepen-
      dently. The higher the number, the more debug output will be
      dently. The higher the number, the more debug output will be
      printed. Valid loglevels are:
      printed. Valid loglevels are:


Line 313: Line 373:


       --show
       --show
      Show information about the selected option. For example, to see
      Show information about the selected option. For example, to see
      options for a connected fx2lafw device:
      options for a connected fx2lafw device:


      $ sigrok-cli --driver fx2lafw --show
      $ sigrok-cli --driver fx2lafw --show


      In order to properly get device options for your hardware, some
      In order to properly get device options for your hardware, some
      drivers might need a serial port specified:
      drivers might need a serial port specified:


      $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show
      $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show


      This also works for protocol decoders, input modules and output
      This also works for protocol decoders, input modules and output
      modules:
      modules:


Line 338: Line 398:
      demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0
      demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0
      A1 A2 A3
      A1 A2 A3
      fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5
      fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5
      6 7
      6 7


      However, not all devices are auto-detectable (e.g. serial port
      However, not all devices are auto-detectable (e.g. serial port
      based ones).   For those you'll have to provide a conn option,
      based ones). For those you'll have to provide a conn option,
      see above.
      see above.


Line 360: Line 420:
      Acquire <numsamples> samples, then quit.
      Acquire <numsamples> samples, then quit.


      You can optionally follow the number by k, m, or g to specify
      You can optionally follow the number by k, m, or g to specify
      the number of samples in kilosamples, megasamples, or gigasam-
      the number of samples in kilosamples, megasamples, or gigasam-
      ples, respectively.
      ples, respectively.


Line 373: Line 433:


       --get <variable>
       --get <variable>
      Get the value of <variable> from the specified device and print
      Get the value of <variable> from the specified device and print
      it.
      it.


       --set  Set one or more variables specified with the --config option,
       --set  Set one or more variables specified with the --config option,
      without doing any acquisition.
      without doing any acquisition.


EXAMPLES
EXAMPLES
       In order to get exactly 100 samples from the connected fx2lafw-sup-
       In order to get exactly 100 samples from the connected fx2lafw-sup-
       ported logic analyzer hardware, run the following command:
       ported logic analyzer hardware, run the following command:


Line 393: Line 453:
sigrok-cli --driver fx2lafw --time 3s
sigrok-cli --driver fx2lafw --time 3s


       To capture data from the first 4 channels using the Openbench Logic
       To capture data from the first 4 channels using the Openbench Logic
       Sniffer lasting 100ms at 10 MHz starting at the trigger condition
       Sniffer lasting 100ms at 10 MHz starting at the trigger condition
      0:high, 1:rising, 2:low, 3:high, use:
      0:high, 1:rising, 2:low, 3:high, use:
Line 413: Line 473:


BUGS
BUGS
       Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or on
       Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or on
       the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net).
       the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net).


LICENSE
LICENSE
       sigrok-cli is covered by the GNU General Public License (GPL). Some
       sigrok-cli is covered by the GNU General Public License (GPL). Some
       portions are licensed under the "GPL v2 or later", some under "GPL v3
       portions are licensed under the "GPL v2 or later", some under "GPL v3
       or later".
       or later".


Line 424: Line 484:
       Please see the individual source code files.
       Please see the individual source code files.


       This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>.   It
       This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>. It
       is licensed under the terms of the GNU GPL (version 2 or later).
       is licensed under the terms of the GNU GPL (version 2 or later).






May 04, 2014 SIGROK-CLI(1)
      October 22, 2018 SIGROK-CLI(1)
</pre>
</pre>
== Screenshots ==
=== sigrok-cli in action: logic data, decoder output, analog data ===
[[File:Sigrok-cli-screenshot-1.png]]

Revision as of 12:06, 20 January 2019

sigrok-cli (sometimes abbreviated as "cli") is a command-line frontend for sigrok.

It is licensed under the terms of the GNU GPL, version 3 or later.

Getting the code

$ git clone git://sigrok.org/sigrok-cli

You can also browse the source code via gitweb.

Distribution packages

See Downloads.

Building from source

See Building.

Manpage

SIGROK-CLI(1)		    General Commands Manual		 SIGROK-CLI(1)



NAME
       sigrok-cli - Command-line client for the sigrok software

SYNOPSIS
       sigrok-cli [OPTIONS] [COMMAND]

DESCRIPTION
       sigrok-cli  is  a  cross-platform  command  line utility for the sigrok
       software.

       It cannot display graphical output, but	is  still  sufficient  to  run
       through the whole process of hardware initialization, acquisition, pro-
       tocol decoding and saving the session.

       It is useful for running on remote or embedded systems, netbooks, PDAs,
       and  for  various  other  use-cases. It can display samples on standard
       output or save them in various file formats.

OPTIONS
       -h, --help
	      Show a help text and exit.

       -V, --version
	      Show sigrok-cli version and the versions of libraries used.

       -L, --list-supported
	      Show information about supported hardware  drivers,  input  file
	      formats, output file formats, and protocol decoders.

       -d, --driver <drivername>
	      A  driver  must always be selected (unless doing a global scan).
	      Use the -L (--list-supported) option to get a list of  available
	      drivers.

	      Drivers  can  take  options,  in the form key=value separated by
	      colons.

	      Drivers communicating with hardware via  a  serial  port	always
	      need  the port specified as the conn option. For example, to use
	      the Openbench Logic Sniffer:

		$ sigrok-cli --driver=ols:conn=/dev/ttyACM0 [...]

	      Some USB devices don't use a unique VendorID/ProductID  combina-
	      tion,  and  thus need that specified as well. This also uses the
	      conn option, using either VendorID.ProductID or bus.address:

	      USB VendorID.ProductID example:

		$ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 [...]

	      USB bus.address example:

		$ sigrok-cli --driver=uni-t-ut61e:conn=4.6 [...]

       -c, --config <deviceoption>
	      A colon-separated list of  device  options,  where  each	option
	      takes the form key=value.  For example, to set the samplerate to
	      1MHz on a device supported by  the  fx2lafw  driver,  you  might
	      specify

		$ sigrok-cli -d fx2lafw --config samplerate=1m [...]

	      Samplerate  is  an  option  common  to most logic analyzers. The
	      argument specifies the samplerate in Hz. You  can  also  specify
	      the samplerate in kHz, MHz or GHz.  The following are all equiv-
	      alent:

		$ sigrok-cli -d fx2lafw --config samplerate=1000000 [...]

		$ sigrok-cli -d fx2lafw --config samplerate=1m [...]

		$ sigrok-cli -d fx2lafw --config "samplerate=1 MHz" [...]

       -i, --input-file <filename>
	      Load input from a file instead of a  hardware  device.  You  can
	      specify  "-" to use stdin as input. If the --input-format option
	      is not supplied, sigrok-cli attempts to autodetect the file for-
	      mat of the input file.

	      Example for loading a sigrok session file:

		$ sigrok-cli -i example.sr [...]

	      Example for loading a WAV file (autodetection of input format):

		$ sigrok-cli -i example.wav [...]

	      Example  for  loading  a	VCD  file from stdin (autodetection of
	      input format):

		$ cat example.vcd | sigrok-cli -i - [...]

       -I, --input-format <format>
	      When loading an input file, assume it's in the specified format.
	      If  this	option	is not supplied (in addition to --input-file),
	      sigrok-cli attempts to autodetect the file format of  the  input
	      file.  Use  the  -L  (--list-supported)  option to see a list of
	      available input formats.

	      The format name may optionally be followed by a  colon-separated
	      list of options, where each option takes the form key=value.

	      Example for loading a binary file with options:

		$ sigrok-cli -i example.bin
			     -I binary:numchannels=4:samplerate=1mhz [...]

       -o, --output-file <filename>
	      Save  output  to	a  file  instead  of writing it to stdout. The
	      default format used when saving is the sigrok session file  for-
	      mat. This can be changed with the --output-format option.

	      Example for saving data in the sigrok session format:

		$ sigrok-cli [...] -o example.sr

       -O, --output-format <format>
	      Set  the	output	format	to  use. Use the -L (--list-supported)
	      option to see a list of available output formats.

	      The format name may optionally be followed by a  colon-separated
	      list of options, where each option takes the form key=value.

	      For  example, the bits or hex formats, for an ASCII bit or ASCII
	      hexadecimal display, can take a "width" option,  specifying  the
	      number  of  samples  (in	bits)  to  display  per  line. Thus -O
	      hex:width=128 will display 128 bits per line, in hexadecimal:

	       0:ffff ffff ffff ffff ffff ffff ffff ffff
	       1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00

	      The lines always start with the  channel	number	(or  name,  if
	      defined),  followed  by  a  colon. If no format is specified, it
	      defaults to bits:width=64, like this:

	       0:11111111 11111111 11111111 11111111 [...]
	       1:11111111 00000000 11111111 00000000 [...]

	      Example for saving data in the CSV format with options:

		$ sigrok-cli [...] -o example.csv -O csv:dedup:header=false

	      Notice that boolean options are true when no value  gets	speci-
	      fied.

       -C, --channels <channellist>
	      A comma-separated list of channels to be used in the session.

	      Note  that  sigrok  always  names  the channels according to how
	      they're shown on the enclosure of the hardware.  If  your  logic
	      analyzer	numbers the channels 0-15, that's how you must specify
	      them with this option. An oscilloscope's channels  would	gener-
	      ally  be referred to as "CH1", "CH2", and so on.	Use the --show
	      option to see a list of channel names for your device.

	      The default is to use all the channels available	on  a  device.
	      You  can	name  a channel like this: 1=CLK.  A range of channels
	      can also be given, in the form 1-5.

	      Example:

		$ sigrok-cli --driver fx2lafw --samples 100
			     --channels 1=CLK,2-4,7
	       CLK:11111111 11111111 11111111 11111111 [...]
		 2:11111111 11111111 11111111 11111111 [...]
		 3:11111111 11111111 11111111 11111111 [...]
		 4:11111111 11111111 11111111 11111111 [...]
		 7:11111111 11111111 11111111 11111111 [...]

	      The comma-separated list is processed from left to  right,  i.e.
	      items  farther to the right override previous items. For example
	      1=CS,CS=MISO will set the name of channel 1 to MISO.

       -g, --channel-group <channel group>
	      Specify the channel group to operate on. Some  devices  organize
	      channels	into groups, the settings of which can only be changed
	      as a group. The list of channel groups,  if  any,  is  displayed
	      with the --show command.

	      Examples:

		$ sigrok-cli -g CH1 [...]

		$ sigrok-cli -d demo -g Logic -c pattern=graycode [...]

       -t, --triggers <triggerlist>
	      A  comma-separated  list	of triggers to use, of the form <chan-
	      nel>=<trigger>.  You can use the name or number of the  channel,
	      and the trigger itself is a series of characters:

	      0 or 1: A low or high value on the pin.
	      r  or  f: A rising or falling value on the pin. An r effectively
	      corresponds to 01.
	      e: Any kind of change on a pin (either a	rising	or  a  falling
	      edge).

	      Not  every  device  supports all of these trigger types. Use the
	      --show command to see which triggers your device supports.

       -w, --wait-trigger
	      Don't output any sample data (even  if  it's  actually  received
	      from the hardware) before the trigger condition is met. In other
	      words, do not output any pre-trigger data. This option is useful
	      if  you  don't  care about the data that came before the trigger
	      (but the hardware delivers this data to sigrok nonetheless).

       -P, --protocol-decoders <list>
	      This option allows the user to specify a comma-separated list of
	      protocol	decoders  to be used in this session. The decoders are
	      specified by their ID, as shown  in  the	-L  (--list-supported)
	      output.

	      Example:

	       $ sigrok-cli -i <file.sr> -P i2c

	      Each protocol decoder can optionally be followed by a colon-sep-
	      arated list  of  options,  where	each  option  takes  the  form
	      key=value.

	      Example:

	       $ sigrok-cli -i <file.sr>
			    -P uart:baudrate=115200:parity_type=odd

	      The  list  of supported options depends entirely on the protocol
	      decoder. Every protocol decoder has different  options  it  sup-
	      ports.

	      Any  "options"  specified  for  a protocol decoder which are not
	      actually supported options, will be interpreted as being channel
	      name/number assignments.

	      Example:

	       $ sigrok-cli -i <file.sr>
			    -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0

	      In this example, wordsize is an option supported by the spi pro-
	      tocol decoder. Additionally, the user tells sigrok to decode the
	      SPI  protocol  using channel 1 as MISO signal for SPI, channel 5
	      as MOSI, channel 3 as CLK, and channel 0 as CS# signal.

	      Notice that the sigrok-cli application does  not	support  "name
	      matching".  Instead  it's  assumed  that the traces in the input
	      stream match the order of the decoder's input signals,  or  that
	      users  explicitly  specify  the  input channel to decoder signal
	      mapping.

	      When multiple decoders are specified in the same -P option, they
	      will be stacked on top of each other in the specified order.

	      Example:

	       $ sigrok-cli -i <file.sr> -P i2c,eeprom24xx
	       $ sigrok-cli -i <file.sr> -P uart:baudrate=31250,midi

	      When multiple -P options are specified, each of them creates one
	      decoder stack, which  executes  in  parallel  to	other  decoder
	      stacks.

	      Example:

	       $ sigrok-cli -i <file.sr> -P uart:tx=D0:rx=D1 -P timing:data=D2


       -A, --protocol-decoder-annotations <annotations>
	      By  default,  all  annotation output of all protocol decoders is
	      shown. With this option a specific decoder's annotations can  be
	      selected for display, by specifying the decoder ID:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c

	      If  a  protocol decoder has multiple annotation classes, you can
	      also specify which one of them to show by specifying  its  short
	      description like this:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read

	      Select  multiple	annotation  classes  by separating them with a
	      colon:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read:data-write

	      You can also select multiple protocol decoders, with an optional
	      selected annotation class each, by separating them with commas:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read:data-write,edid

       -M, --protocol-decoder-meta <pdname>
	      When given, show protocol decoder meta output instead of annota-
	      tions.  The argument is the name of the decoder whose meta  out-
	      put to show.

	       $ sigrok-cli -i <file.sr> -M i2c

	      Not every decoder generates meta output.

       -B, --protocol-decoder-binary <binaryspec>
	      When  given,  decoder  "raw" data of various kinds is written to
	      stdout instead of annotations (this could be raw binary UART/SPI
	      bytes,  or  WAV  files, PCAP files, PNG files, or anything else;
	      this is entirely dependent on the  decoder  and  what  kinds  of
	      binary output make sense for that decoder).

	      No  other  information is printed to stdout, so this is suitable
	      for piping into other programs or saving to a file.

	      Protocol decoders that support binary output publish a  list  of
	      binary classes, for example the UART decoder might have "TX" and
	      "RX". To select TX for output, the argument to this option would
	      be:

	       $ sigrok-cli -i <file.sr> -B uart=tx

	      If only the protocol decoder is specified, without binary class,
	      all classes are written to stdout:

	       $ sigrok-cli -i <file.sr> -B uart

	      (this is only useful in rare cases, generally you would  specify
	      a certain binary class you're interested in)

	      Not every decoder generates binary output.

       --protocol-decoder-samplenum
	      When  given,  decoder  annotations  will include sample numbers,
	      too.  This allows consumers to receive machine  readable	timing
	      information.

       -l, --loglevel <level>
	      Set  the	libsigrok  and libsigrokdecode loglevel. At the moment
	      sigrok-cli doesn't support setting the  two  loglevels  indepen-
	      dently.  The  higher  the  number, the more debug output will be
	      printed. Valid loglevels are:

	      0   None
	      1   Error
	      2   Warnings
	      3   Informational
	      4   Debug
	      5   Spew

       --show
	      Show information about the selected option. For example, to  see
	      options for a connected fx2lafw device:

	       $ sigrok-cli --driver fx2lafw --show

	      In  order to properly get device options for your hardware, some
	      drivers might need a serial port specified:

	       $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show

	      This also works for protocol decoders, input modules and	output
	      modules:

	       $ sigrok-cli --protocol-decoders i2c --show
	       $ sigrok-cli --input-format csv --show
	       $ sigrok-cli --output-format bits --show

       --scan Scan for devices that can be detected automatically.

	      Example:

	       $ sigrok-cli --scan
	       The following devices were found:
	       demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0
	      A1 A2 A3
	       fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4  5
	      6 7

	      However,	not  all devices are auto-detectable (e.g. serial port
	      based ones).  For those you'll have to provide  a  conn  option,
	      see above.

	       $ sigrok-cli --driver digitek-dt4000zc:conn=/dev/ttyUSB0 --scan
	       The following devices were found:
	       Digitek DT4000ZC with 1 channel: P1

       --time <ms>
	      Sample for <ms> milliseconds, then quit.

	      You can optionally follow the number by s to specify the time to
	      sample in seconds.

	      For example, --time 2s will sample for two seconds.

       --samples <numsamples>
	      Acquire <numsamples> samples, then quit.

	      You can optionally follow the number by k, m, or	g  to  specify
	      the  number  of samples in kilosamples, megasamples, or gigasam-
	      ples, respectively.

	      For example, --samples 3m will acquire 3000000 samples.

       --frames <numframes>
	      Acquire <numframes> frames, then quit.

       --continuous
	      Sample continuously until stopped. Not all devices support this.

       --get <variable>
	      Get the value of <variable> from the specified device and  print
	      it.

       --set  Set  one	or  more variables specified with the --config option,
	      without doing any acquisition.

EXAMPLES
       In order to get exactly 100 samples  from  the  connected  fx2lafw-sup-
       ported logic analyzer hardware, run the following command:

	 sigrok-cli --driver fx2lafw --samples 100

       If you want to sample data for 3 seconds (3000 ms), use:

	 sigrok-cli --driver fx2lafw --time 3000

       Alternatively, you can also use:

	 sigrok-cli --driver fx2lafw --time 3s

       To  capture  data  from	the first 4 channels using the Openbench Logic
       Sniffer lasting 100ms at 10 MHz starting at the trigger condition
	      0:high, 1:rising, 2:low, 3:high, use:

       sigrok-cli --driver ols:conn=/dev/ttyACM0 --config samplerate=10m \
	      --output-format bits --channels 0-3 --wait-trigger \
	      --triggers 0=1,1=r,2=0,3=1 --time 100

       To turn on internal logging on a Lascar EL-USB series device:

       sigrok-cli --driver lascar-el-usb:conn=10c4.0002 \
	      --config datalog=on --set

EXIT STATUS
       sigrok-cli exits with 0 on success, 1 on most failures.

SEE ALSO
       pulseview(1)

BUGS
       Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or  on
       the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net).

LICENSE
       sigrok-cli  is  covered	by  the GNU General Public License (GPL). Some
       portions are licensed under the "GPL v2 or later", some under  "GPL  v3
       or later".

AUTHORS
       Please see the individual source code files.

       This  manual  page was written by Uwe Hermann <uwe@hermann-uwe.de>.  It
       is licensed under the terms of the GNU GPL (version 2 or later).



			       October 22, 2018 		 SIGROK-CLI(1)