The [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345.html MASTECH MAS345] is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity.
The [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345.html MASTECH MAS345] is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity.


It is also sold under the names '''Velleman DVM345DI''', '''McVoice M-345pro''', and '''Sinometer MAS345'''.
It is also sold under the names [http://www.velleman.eu/products/view/?country=ot&lang=de&id=341708 Velleman DVM345DI], [http://www.xlsmess.de/html/mcvoice_-_m-345pro.html McVoice M-345pro], and [http://www.sinometer.com/jpg/MAS345.jpg Sinometer MAS345].
 
Manual: [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345_hys004695.pdf Original version] (2008), [http://www.elv-downloads.de/service/manuals_hw/45988_MAS345_UM.pdf German version from ELV] (2002)
 
Software: [http://www.elv-downloads.de/service/manuals_hw/45988_MAS345_Software_V20.zip "DMM VIEW" version 2.0] (from ELV; for Win98/NT/ME/2000/XP; supports MAS343, MAS344, MAS345, M9803R)


See [[MASTECH MAS345/Info]] for more details about the device.
See [[MASTECH MAS345/Info]] for more details about the device.
Line 13: Line 9:
'''Multimeter''':
'''Multimeter''':


* '''Main chip:''' MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
* '''Main chip''': MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
* '''[http://datasheet.octopart.com/M74HC4060B1R-STMicroelectronics-datasheet-10836214.pdf ST 74HC4060 N00U732]: 14-Stage Binary Counter/Oscillator
* '''14-stage binary counter/oscillator''': [http://datasheet.octopart.com/M74HC4060B1R-STMicroelectronics-datasheet-10836214.pdf ST 74HC4060 N00U732]
* '''?''': Texas Instruments 12AL9JM 0P07CP
* '''?''': Texas Instruments 12AL9JM 0P07CP
* '''?''': GC7555AP AA7057HS
* '''?''': GC7555AP AA7057HS
Line 157: Line 153:
== Resources ==
== Resources ==


* [http://www.elv.de/controller.aspx?cid=683&detail=10&detail2=211397 elv.de: Download zu: Digital-Multimeter MAS-345  (68-04 59 88)] (German manual, software)
* [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345_hys004695.pdf Original English vendor manual] (2008)
* [http://www.elv.de/controller.aspx?cid=683&detail=10&detail2=211397 elv.de: Download zu: Digital-Multimeter MAS-345  (68-04 59 88)]:
** [http://www.elv-downloads.de/service/manuals_hw/45988_MAS345_UM.pdf German manual from ELV] (2002)
** [http://www.elv-downloads.de/service/manuals_hw/45988_MAS345_Software_V20.zip "DMM VIEW" software, version 2.0] (for Win98/NT/ME/2000/XP; supports MAS343, MAS344, MAS345, M9803R)
* [http://www.cczwei-forum.de/cc2/thread.php?threadid=3452 cczwei-forum.de: C# software for reading DMM values]

Revision as of 00:04, 8 July 2012

The MASTECH MAS345 is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity.

It is also sold under the names Velleman DVM345DI, McVoice M-345pro, and Sinometer MAS345.

See MASTECH MAS345/Info for more details about the device.

Hardware

Multimeter:

  • Main chip: MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
  • 14-stage binary counter/oscillator: ST 74HC4060 N00U732
  • ?: Texas Instruments 12AL9JM 0P07CP
  • ?: GC7555AP AA7057HS
  • ?: Sharp B B5 PC817
  • ?: Sharp B B6 PC817
  • Crystal: ca. 32kHz
  • Fuse: 15A/250V (6x30mm) (for the 10A jack; interestingly the PCB silkscreen says "20A" for that jack)

RS232 cable:

  • TODO.

Photos

TODO.

Protocol

The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different).

  • Serial port settings: 600 baud, 7n2, DTR on
  • Every time the host sends a (any?) character to the DMM (the vendor software sends D/0x44), it returns 14 ASCII bytes containing the measurement value and so on. The documentation states that a request interval of >= 1 second is "required for stable measuring data from meter".

Packet format:

Byte(s) Description
1-2 Measuring mode (DC, AC, OH, CA, TE, DI, ...)
3 Always a space (?)
4 Sign ('-' or ' ', i.e. a minus or a space)
5-9 Decimal point and current measurement value (Examples: 10.00, 0L, 3.999)
10-13 Unit (Examples: V, mV, A, mA, kOhm, MOhm, nF, ...)
14 Carriage return (13/0x0d)

Example packets:

01 02 03 04 05 06 07 08 09 10 11 12 13 14
D C - 0 0 0 . 0 V \r
A C 0 0 . 0 0 A \r
C A 0 . 0 7 1 n F \r
O H O . L M O h m \r

Resources