Difference between revisions of "Gossen Metrawatt Metrahit 16I"

From sigrok
Jump to navigation Jump to search
Line 160: Line 160:
| 10 mΩ
| 10 mΩ
| rowspan="2" | ±(0,5% + 3)
| rowspan="2" | ±(0,5% + 3)
|
| mq Res., unit Ω, mqflags -
|
|


Line 166: Line 166:
| 300.0 Ω
| 300.0 Ω
| 100 mΩ
| 100 mΩ
|
| "
|
|


Line 173: Line 173:
| 1 Ω
| 1 Ω
| rowspan="3" | ±(0,4% + 1)
| rowspan="3" | ±(0,4% + 1)
|  
| "
|
|


Line 179: Line 179:
| 30.00 kΩ
| 30.00 kΩ
| 10 Ω
| 10 Ω
|  
| "
|
|


Line 185: Line 185:
| 300.0 kΩ
| 300.0 kΩ
| 100 Ω
| 100 Ω
|  
| "
|
|


Line 192: Line 192:
| 1 kΩ
| 1 kΩ
| ±(0,6% + 1)
| ±(0,6% + 1)
|  
| "
|
|


Line 199: Line 199:
| 10 kΩ
| 10 kΩ
| ±(2,0% + 1)
| ±(2,0% + 1)
|  
| "
|
|


Line 207: Line 207:
| 1 mV
| 1 mV
| ±(0,25% + 1)
| ±(0,25% + 1)
|
| mq V, unit V, mqflags DC,DIODE
|
|


Line 215: Line 215:
| 10 pF
| 10 pF
| rowspan="3" | ±(1,0% + 3)
| rowspan="3" | ±(1,0% + 3)
|  
| mq Cap., unit F, mqflags -
|
|


Line 221: Line 221:
| 300.0 nF
| 300.0 nF
| 100 pF  
| 100 pF  
|  
| "
|
|


Line 227: Line 227:
| 3.000 µF
| 3.000 µF
| 1 nF
| 1 nF
|  
| "
|
|


Line 234: Line 234:
| 10 nF
| 10 nF
| ±(3,0% + 3)
| ±(3,0% + 3)
|  
| "
|
|


|-
|-
| rowspan="4" | Hz
| rowspan="4" | Hz=
| 300.00 Hz
| 300.0 Hz
| 0.01 Hz
| 0.01 Hz
| rowspan="4" | ±(0.1% + 3)
| rowspan="4" | ±(0.1% + 3)
| mq Freq., unit Hz, mqflags DC
|
|-
| 3.000 kHz
| 0.1 Hz
| "
|
|
|-
| 30.00 kHz
| 1 Hz
| "
|
|-
| 100.00 kHz
| 10 Hz
| "
|
|-
| rowspan="4" | Hz≈
| 300.0 Hz
| 0.01 Hz
| rowspan="4" | ±(0.1% + 3)
| mq Freq., unit Hz, mqflags AC
|
|


|-
|-
| 3.0000 kHz
| 3.000 kHz
| 0.1 Hz
| 0.1 Hz
|  
| "
|
|


|-
|-
| 30.000 kHz
| 30.00 kHz
| 1 Hz
| 1 Hz
|  
| "
|
|


|-
|-
| 100.000 kHz
| 100.00 kHz
| 10 Hz
| 10 Hz
|  
| "
|
|


Line 268: Line 294:
| –200.0 - +200.0 °C
| –200.0 - +200.0 °C
| 2 Kelvin + 5
| 2 Kelvin + 5
|  
| mq Temp., unit °C, mqflags -
|
|


Line 274: Line 300:
| +200.0 - +800.0 °C
| +200.0 - +800.0 °C
| ±(1.0% + 5)
| ±(1.0% + 5)
|
| "
|
|


Line 281: Line 307:
| –100.0 - +200.0 °C
| –100.0 - +200.0 °C
| 2 Kelvin + 5
| 2 Kelvin + 5
|
| "
|
|


Line 287: Line 313:
| +200.0 - +800.0 °C
| +200.0 - +800.0 °C
| ±(1.0% + 5)
| ±(1.0% + 5)
|
| "
|
|


Line 305: Line 331:
|   
|   
|
|
|-
| Data Hold 
|
|
| mqflags += HOLD
| Seems not to work on [[User:Matthias Heidbrink | Matthias']] device.
|-
| MIN
|
|
| mqflags += MIN
|
|-
| MAX
|
|
| mqflags += MAX
|
   
   
|-
|-

Revision as of 19:25, 2 November 2013

Gossen Metrawatt Metrahit 16I
Status in progress
Counts 3100 (31000)
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (RS232)
Measurements voltage, current, resistance, capacitance, temperature, diode, continuity
Features autorange, data hold, bargraph
Website [1]

The Gossen Metrawatt Metrahit 16I is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V).

The resolution is one digit higher on the data interface.

Hardware

  • Fuse: None!
  • TODO.

Photos

Measurement functions and ranges

Measurement function Range Resolution Deviation sigriok result Remarks
V= 30 mV 10 μV ±(0,5% + 3) mq V, unit V, mqflags DC Not covered by autorange, use manual range
300 mV 100 μV ±(0,5% + 3) " Not covered by autorange, use manual range
3 V 1 mV ±(0,25% + 1) "
30 V 10 mV "
300 V 100 mV "
600 V 1 V ±(0,35% + 1) "
V≈ 3 V 100 μV ±(1.0% + 3) (> 10 Digit) mq V, unit V, mqflags AC,RMS
30 V 100 μV "
300 V 1 mV "
1000 V 10 mV "
V≃ 3 V 100 μV ±(1.0% + 3) (> 10 Digit) mq V, unit V, mqflags AC,DC,RMS
30 V 100 μV "
300 V 1 mV "
1000 V 10 mV "
A≈ (Clamp only)  30 A 10 mA ±(2,5% + 3) (>10 Digit) mq Curr., unit A, mqflags AC,DC,RMS Current clamp with 100 mV/A required, e.g. GMC WZ12B
100 A 100 mA "
Ω 30.00 Ω 10 mΩ ±(0,5% + 3) mq Res., unit Ω, mqflags -
300.0 Ω 100 mΩ "
3.000 kΩ 1 Ω ±(0,4% + 1) "
30.00 kΩ 10 Ω "
300.0 kΩ 100 Ω "
3.000 MΩ 1 kΩ ±(0,6% + 1) "
30.00 MΩ 10 kΩ ±(2,0% + 1) "
Diode/Cont. 3.0000 V– 1 mV ±(0,25% + 1) mq V, unit V, mqflags DC,DIODE
Cap. F 30.00 nF 10 pF ±(1,0% + 3) mq Cap., unit F, mqflags -
300.0 nF 100 pF "
3.000 µF 1 nF "
30.00 µF 10 nF ±(3,0% + 3) "
Hz= 300.0 Hz 0.01 Hz ±(0.1% + 3) mq Freq., unit Hz, mqflags DC
3.000 kHz 0.1 Hz "
30.00 kHz 1 Hz "
100.00 kHz 10 Hz "
Hz≈ 300.0 Hz 0.01 Hz ±(0.1% + 3) mq Freq., unit Hz, mqflags AC
3.000 kHz 0.1 Hz "
30.00 kHz 1 Hz "
100.00 kHz 10 Hz "
°C Pt100 –200.0 - +200.0 °C 2 Kelvin + 5 mq Temp., unit °C, mqflags -
+200.0 - +800.0 °C ±(1.0% + 5) "
Pt1000 –100.0 - +200.0 °C 2 Kelvin + 5 "
+200.0 - +800.0 °C ±(1.0% + 5) "
Event count
Stop Watch
Data Hold mqflags += HOLD Seems not to work on  Matthias' device.
MIN mqflags += MIN
MAX mqflags += MAX

The column "sigrok result" contains in short form what the driver generates for the resp. data type.