Difference between revisions of "ICStation USBRelay"
(→Protocol: Add protocol description) |
(Change status to supported) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
| image = [[File:ICStation_ICSE012A-mugshot.png|180px]] | | image = [[File:ICStation_ICSE012A-mugshot.png|180px]] | ||
| name = ICStation USBRelay | | name = ICStation USBRelay | ||
| status = | | status = supported | ||
| source_code_dir = icstation-usbrelay | | source_code_dir = icstation-usbrelay | ||
| channels = 2, 4 or 8 | | channels = 2, 4 or 8 | ||
Line 12: | Line 12: | ||
See [[ICStation_USBRelay/Info | Info]] for USB details. | See [[ICStation_USBRelay/Info | Info]] for USB details. | ||
'''WARNING:''' When reconnecting to the device (e.g. with sigrok-cli or SmuView) the connect will fail and the "query device"-command (0x50) will be interpreted as a bit mask and will turn on relays 1-4, 6 and 8. You have to power cycle the device to be able to reconnect! | |||
== Photos == | == Photos == | ||
Line 28: | Line 30: | ||
== Protocol == | == Protocol == | ||
The relay | The relay boards have a very simple and limited protocol. | ||
'''Note:''' Once the device is connected and has entered the command mode (0x51), every following byte will be interpreted as a bit mask for switching relays. There is no way to leave the command mode! | |||
{| border="0" width="95%" style="font-size: smaller;" class="alternategrey sigroktable" | {| border="0" width="95%" style="font-size: smaller;" class="alternategrey sigroktable" | ||
Line 37: | Line 41: | ||
|- | |- | ||
| valign="top" style="white-space=nowrap;" | '''0x50''' | | valign="top" style="white-space=nowrap;" | '''0x50''' | ||
| '''Query the device | | '''Query the device model.''' | ||
Response: | Response: | ||
{| border="0" width="100%" style="margin: 0;" class="alternategrey" | {| border="0" width="100%" style="margin: 0;" class="alternategrey" | ||
|- | |- | ||
| style="width: 3em;" | 0xAB | | style="width: 3em;" | '''0xAB''' | ||
| ICSE012A | | style="width: 6em;" | ICSE012A | ||
| 4 | | 4 relay version | ||
|- | |- | ||
| 0xAD | | '''0xAD''' | ||
| | | ICSE013A | ||
| 2 | | 2 relay version | ||
|- | |- | ||
| 0xAC | | '''0xAC''' | ||
| | | ICSE014A | ||
| 8 | | 8 relay version | ||
|} | |} | ||
|- | |- | ||
| valign="top" style="white-space=nowrap;" | '''0x51''' | | valign="top" style="white-space=nowrap;" | '''0x51''' ''0xnn 0xnn ...'' | ||
| '''Start command mode.''' | | '''Start command mode.''' | ||
Every following byte will be interpreted as a mask for switching the relays. | Every following byte will be interpreted as a bit mask for switching the relays. '''0''' will turn a relay on, '''1''' will turn a relay off. | ||
'''Note:''' You cannot leave the command mode! | |||
Examples for switching mask bytes (ICSE014A, 8 relays): | |||
{| border="0" width="100%" style="margin: 0;" class="alternategrey" | |||
|- | |||
| style="width: 5em;" | '''0b00000001''' | |||
| Turn off relay #1 and turn on relays #2 - #8 | |||
|- | |||
| '''0b00000000''' | |||
| Turn on all relays (#1 - #8) | |||
|- | |||
| '''0b10101010''' | |||
| Turn off relay #1, #3, #5, #7 and turn on relays #2, #4, #6, #8 | |||
|} | |||
|} | |} | ||
Line 97: | Line 116: | ||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Multiplexer]] | [[Category:Multiplexer]] | ||
[[Category: | [[Category:Supported]] |
Latest revision as of 18:10, 19 February 2023
Status | supported |
---|---|
Source code | icstation-usbrelay |
Channels | 2, 4 or 8 |
Ratings | 10A @ 250VAC/30VDC, 12A @ 125VAC/28VDC |
Connectivity | USB/Serial |
The ICStation USBRelay is a USB relay card with up to 8 relays. Models with 2 (ICSE013A), 4 (ICSE012A) and 8 (ICSE014A) relays exist.
See Info for USB details.
WARNING: When reconnecting to the device (e.g. with sigrok-cli or SmuView) the connect will fail and the "query device"-command (0x50) will be interpreted as a bit mask and will turn on relays 1-4, 6 and 8. You have to power cycle the device to be able to reconnect!
Photos
Hardware
- STM 8S003F3P6 microcontroller: datasheet
- Prolific PL-2303HX USB to UART Bridge: datasheet
- ULN2803AG relay driver: datasheet
Protocol
The relay boards have a very simple and limited protocol.
Note: Once the device is connected and has entered the command mode (0x51), every following byte will be interpreted as a bit mask for switching relays. There is no way to leave the command mode!
Byte | Command | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
0x50 | Query the device model.
Response:
| |||||||||
0x51 0xnn 0xnn ... | Start command mode.
Every following byte will be interpreted as a bit mask for switching the relays. 0 will turn a relay on, 1 will turn a relay off. Note: You cannot leave the command mode! Examples for switching mask bytes (ICSE014A, 8 relays):
|
Example use
Detect the device and display its properties.
$ sigrok-cli -d icstation-usbrelay:conn=/dev/ttyUSB0 --show Driver functions: Multiplexer Scan options: conn serialcomm icstation-usbrelay - ICStation ICSE012A Channel groups: R1: channel R2: channel R3: channel R4: channel Supported configuration options across all channel groups: enabled: on, off
Manipulate the state of relays.
$ sigrok-cli -d icstation-usbrelay:conn=/dev/ttyUSB0 --config channel_group=R1:enabled=off --config channel_group=R2:enabled=on --set