Difference between revisions of "Siemens B1026"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
|  (Created page with "{{Infobox multimeter | image           = <!-- 180px --> | name            = Siemens B1026 | status          = supported | source_code_dir = norma-dmm ...") |  (Added pics.) | ||
| (2 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| {{Infobox multimeter | {{Infobox multimeter | ||
| | image           =  | | image           = [[File:siemens_b1026_logo.png|180px]] | ||
| | name            = Siemens B1026 | | name            = Siemens B1026 | ||
| | status          = supported | | status          = supported | ||
| | source_code_dir = norma-dmm | | source_code_dir = norma-dmm | ||
| | counts          = 21000 | | counts          = 21000 | ||
| | categories      = CAT II 600  | | categories      = CAT II 600 V | ||
| | connectivity    = RS232, proprietary cable | | connectivity    = RS232, proprietary cable | ||
| | measurements    = voltage, current, resistance, capacitance, temperature, diode, continuity | | measurements    = voltage, current, resistance, capacitance, temperature, diode, continuity | ||
| Line 12: | Line 12: | ||
| }} | }} | ||
| The '''Siemens B1026''' is a 21000 counts, handheld digital multimeter with optional RS232 connectivity. | The '''Siemens B1026''' is a 21000 counts, CAT II (600 V) handheld digital multimeter with optional RS232 connectivity. | ||
| See [[Norma DM950]] for further information on all models of the series, including RS232 interface. | The RS232 interface requires an internal interface board (below the 5 holes in the back of the case), a special cable and (for use with PC) adaptor. Depending on the model, they came with the device or were available as accessory ''Interface B9102, 7KB9102-8DD''. | ||
| See [[Norma DM950]] for further information on all models of the series, including RS232 interface.   | |||
| == Hardware == | == Hardware == | ||
| Line 26: | Line 28: | ||
| '''Multimeter''': | '''Multimeter''': | ||
| <gallery> | <gallery> | ||
| File: | File:Siemens_b1026_1.png|<small>Front (with rubber holster)</small> | ||
| File: | File:Siemens_b1026_4.png|<small>Front (without holster)</small> | ||
| File: | File:Siemens_b1026_2.png|<small>Back (without holster)</small> | ||
| File:Siemens_b1026_3.png|<small>Inside (without RS232 interface board)</small> | |||
| File: | |||
| </gallery> | </gallery> | ||
| == Resources == | == Resources == | ||
Latest revision as of 14:35, 11 June 2014
|  | |
| Status | supported | 
|---|---|
| Source code | norma-dmm | 
| Counts | 21000 | 
| IEC 61010-1 | CAT II 600 V | 
| Connectivity | RS232, proprietary cable | 
| Measurements | voltage, current, resistance, capacitance, temperature, diode, continuity | 
| Features | autorange, data hold, bargraph, backlight | 
| Website | set.nl | 
The Siemens B1026 is a 21000 counts, CAT II (600 V) handheld digital multimeter with optional RS232 connectivity.
The RS232 interface requires an internal interface board (below the 5 holes in the back of the case), a special cable and (for use with PC) adaptor. Depending on the model, they came with the device or were available as accessory Interface B9102, 7KB9102-8DD.
See Norma DM950 for further information on all models of the series, including RS232 interface.
Hardware
- Fuses
- 2A: F 2A/250V DIN 41660-F2
- 10A: FF 12,5A/500 V, >20kA/AC
 
- TODO
Photos
Multimeter: